:: À¯ºÐ³óµµÃøÁ¤±â
  :: ºñÁß.¹ÐµµÃøÁ¤±â
  :: SDIÃøÁ¤±â
  :: »ïÅõ¾ÐÃøÁ¤±â
  :: ATP METER
  :: TOC ÃøÁ¤±â
  :: ¼öÁú°¡½º(CO2)ÃøÁ¤±â
  :: °øÁß±Õ»ùÇ÷¯
  :: À¯¼Ó°è/À¯·®°è
  :: ¼ö½ÉÃøÁ¤±â
  :: ä¼ö±â
  :: ÇÁ¶ûÅ©Åæ³×Æ®
  :: ä´Ï±â
  :: Á߱ݼÓÃøÁ¤±â
  :: ORP METER
  :: ÀÚµ¿ÀûÁ¤ÀåÄ¡
  :: PACK TEST
  :: TDS METER
  :: ¼öÀººÐ¼®±â
  :: ÃÑÀÎ.ÃÑÁú¼ÒÃøÁ¤±â
  :: PH METER
  :: DO METER
  :: Àüµµµµ ÃøÁ¤±â
  :: COD METER
  :: BOD METER
  :: MLSS METER
  :: ½ÄÇ°ÃøÁ¤±â
  :: Ź.»öµµ°è
  :: Źµµ°è/Åõ½Ãµµ°è
  :: »öµµ°è
  :: ´ÙÇ׸ñ¼öÁúÃøÁ¤±â
  :: Á߱ݼÓÆó¾×ó¸®ÀåÄ¡
  :: °ø¾÷¿ë¼öÁúÃøÁ¤±â
  :: ÀÌ¿ÂÃøÁ¤±â
  :: ÀÜ·ù¿°¼ÒÃøÁ¤±â
  :: ¿°ºÐÃøÁ¤±â
  :: ¿ÀÁ¸ÃøÁ¤±â
  :: ´ëÀå/ÀϹݼ¼±Õ½ÃÇèÁö


  home < orderlist
 
 


U.S.A MAT-030
Á¦Á¶»ç : U.S.A
»óÇ°À̸§ : MAT-030
ÆǸŰ¡ : º°µµ¹®ÀÇ
Ä«Å×°í¸® : »ïÅõ¾ÐÃøÁ¤±â
Àç°í»óÅ : Àç°í ÀÖÀ½
      

»óÇ°Á¤º¸  

 

»ïÅõ¾ÐÃøÁ¤±â                 MAT-030

The sample solution is cooled by means of a peltier cooling syste, the temperature being electronically controlled. When the sample olution has reached its target temperature below the freezing point, the crystallization process of the sample is automatically initiated. This is done by injecing ice crystals into the solution (a stainless steel needle is cooled by means of a second cooling system to such an extent that tiny ice crystals stick to its tip; this needle is plunged into the latter is measured with a resolution short time). Hereafter the temperature rises
spontaneously untal it has reached the crystallization of 1.858/1000¡É (see diagram on the above.) The reproducibility of the result depends definitely on the exact initiation of the crystallization process at the standardized supercooling temperature

Specifications
TECHIAL DATA OF THE OSMOMAT 030(Standard instument)
Sample volume 50u1 to 30u1
Duration of measurement approx. one minute
Reproducibility ¡ì¡¾0.5% or ¡ì¡¾2digit for 50 ul
¡ì¡¾1% or ¡ì¡¾4digit for 30ul
Display 4.5 digit
Measuring range up tp approx. 3000 mOsmol/kg
Resolution 1 mOsmol/kg over the entire
measuring range
Initiation of the
crystallization
process
by means of the tip of a stainless steel
needle covered with ice crystals which
is controlled automatically
Cooling by means of two separate peltier
cooling systems with heat dissipation
by air
Lower cooling electronic temperature regulation
deviation ¡ì¡¾0.1¡É
Ambient temperature 10¡É to 35¡É
Power supply 220V(¡¾30V), 50/60Hz, 120VA,
special versions 110V, 100V
Dimensions 220*205*360mm
Weight approx. 7kg
STD Accessories 100 Meas Vessels, 1 Main Cable, 1 Pipette,
2 Fuses,20 Ampules of CAL Sol\'n, 1 Tool

 
  »óÇ°Æò°¡

¼­¿ïƯº°½Ã ¼­Ãʱ¸ ¾çÀ絿 14-8 »ïÈ­°úÇкôµù / TEL : 02-571-2777
´ëÇ¥ÀÚ : ±è ¿µ ¿õ / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±è¿µ¿õ
E-mail : 87samhwa@hanmail.net / »ç¾÷ÀÚµî·Ï¹øÈ£ : 220-81-20569 / Åë½ÅÆǸŽŰí¹øÈ£:
Copyright ¨Ï 2001 ÁÖ½Äȸ»ç »ïÈ­°úÇÐ COMPANY All Rights Reserved.