Standard configuration
  • Measurement of gas concentrations
    • Gas concentrations measured with NDIR sensors: CO2, CH4
    • Gas concentrations measured with electrochemical sensors: O2
    • Toxic gas concentrations measured with electrochemical sensors: CO, NO, NO2, SO2, H2S, H2. Please ask for quote for other gases.
  • Measurement of other parameters
    • Measurement of gas and ambient temperatures
    • Pressure, draft and differential pressure measurements with 1 Pa resolution
    • Soot test according to Bacharach with a pump flow of 1.62 l/min
    • Flow velocity (Option)
    • 6 analogue inputs (2 current/voltage, 2 thermocouple, 2 thermistor)
  • Calculation
    • CO2 concentration
    • Calculation of absolute and relative mass concentrations & relative emissions
    • Calculation of all relevant combustion parameters
  • Processing and presentation of measured data
    • All results shown on display
    • Averaging of all measured values. Averaging time: 10 sec - 60 min
    • Graphical presentation of all measured values as diagram
    • Memory capacity for 1024 sets of data, organised into 10 data banks
    • Up to 9 separate items in a data set
    • User definition of the 9 items
    • Memory capacity for 30 reports
    • Data logger function for the analogue inputs
    • All measured values, stored values or displays can be printed on the internal printer.
    • Powerful PC program for analyser settings and data communication
  • Software-Eigenschaften
    • International compatibility (language, date format etc.)
    • Password protection for settings
    • Automatic zeroing when the analyser is switched on
    • Calibration of O2/CO2 during use
    • All parameters programmable
    • List of 22 common fuels
    • 10 further freely programmable fuels
    • Permanent automatic check of the instruemnt with acoustic warning and full information in the "control list"
    • Compensation of cross sensitivity and temperature drift of gas sensors
  • Hardware capabilities
    • Electronic regulation of the pump flow rate
    • Integrated clock/calendar
    • Internal 57 mm dot-matrix printer
    • Power from rechargeable battery or mains
    • Big (70 x 60 mm) LCD display with backlighting (Graphics or 11 x 21 characters)
    • Gas probe with thermocouple and condensate trap
    • Power for heated probe holder during mains operation
    • RS-232C interface and multifunctional PC program
Optional accessories
    • External ambient temperature sensor
Technical data
    • Size of case WxHxD: 485 x 205 x 295 mm
    • Weight w/o probe: 10 kg
    • Display size: Graphical - LCD, with backlighting and variable contrast, 128 x 112 pixels, 75 x 64 mm
    • Printer: high-speed dot matrix printer with graphics capability for 57 mm normal paper
    • Data memory: Memory for 30 reports and 10 banks containg a total of 1024 sets of data 
    • CO - measurement channel: Separate from the other gas channels. If the freely programmable maximum is exceeded then the sensor is purged with air, without interrupting the other measurements
    • Interface: RS232C